TINME CNC oil mist collector

TM-750A+ CNC Oil Mist Collector

A+ monitoring version

TINME centrifugal CNC oil mist collector with 1,400 m3/h nominal airflow at 50Hz and an added filter monitoring function.

TINME TM-750A+ CNC oil mist collector

The TM-750A+ has the same core performance, dimensions and filtration structure as the corresponding TM-750A model, with an added filter monitoring function. An optional HEPA post-filter is available for micromist, smoke and vapor applications.

Technical Specifications

ModelTM-750A+
Airflow at 50Hz1,400 m3/h
Motor power0.75 kW
Power supply3-phase 220V/380V, 50Hz/60Hz
Motor speed2,850 rpm
Inlet diameter150 mm
Weight40 kg
Dimensions (diameter x height)480 x 950 mm
Filter structureCentrifugal separation, multilayer filter, optional HEPA post-filter
Filtration efficiencyUp to 99.97% at 0.3 micrometers with optional HEPA post-filter
InstallationMachine-top mounting; optional floor or wall-bracket mounting
Filter monitoringIncluded filter monitoring function
Noise levelNeeds Confirmation

Specifications are based on the supplied 50Hz product table. Airflow increases at 60Hz; exact 60Hz airflow values require confirmation.

A+ Filter Monitoring Function

TINME A+ oil mist collector filter monitoring device with status indicator TINME A+ oil mist collector with filter monitor detail

The A+ version adds a monitoring function to the corresponding A model. Its listed airflow, motor, inlet, weight, dimensions, filtration structure and installation options remain the same as the matching A version.

Filtration Process

TINME centrifugal and multilayer oil mist filter structure Optional TINME HEPA post-filter cartridge
  1. Polluted air is drawn from the machine enclosure into the lower pre-chamber.
  2. The rotating turbine generates centrifugal force, causing oil droplets to coalesce.
  3. A multilayer filter captures smaller remaining pollutant particles.
  4. Collected liquid returns through the drainage tube for reuse in the process where appropriate.

Maintenance

Internal filters can be accessed by opening the cover for cleaning or replacement. Maintenance intervals depend on the coolant, particulate load and operating cycle and require application confirmation.

HEPA option: The supplied specification states up to 99.97% filtration at 0.3 micrometers with the optional HEPA post-filter. An H13 classification is not stated in the source document.

Send Inquiry Request Datasheet

Need help selecting an oil mist collector?

Tell us your machine type, enclosure size, coolant and operating conditions.

Request Application Advice